Water Cooled AIO Grading Equipment: Basic Information | |
| Item | Specification |
| Structure | 2 columns and 6 levels. The power supply unit and the pin jig unit are integrated together (AIO). |
| Pass Rate | ≥99.5%(Considering only equipment-related anomalies) |
| Utilization | ≥98% |
| 30-day failure rate | ≤1%(Considering only equipment-related anomalies) |
| Noise | ≤75dB(Measured at 1m away from the noise source) |
Capacity Grading Equipment: Parallel Power Supply Performance Parameters | ||
| Work mode | CCC,CVC,Rest,CCD | |
| Current | Charge current range | 200-200000mA |
| CV cutoff current range | 200-200000mA | |
| Current setting resolution | 1mA | |
| Current accuracy | ±0.05%FS | |
| Voltage | Charge voltage range | 0-5000mV |
| Discharge voltage range | 1800-5000mV | |
| Constant voltage range | 1800-5000mV | |
| Voltage setting resolution | 1mV | |
| Voltage accuracy | ±2mV | |
| Time | Time accuracy | ≤±0.1% |
| Time resolution | 1s | |
| Charge efficiency | ≥78% | |
| Feedback efficiency | ≥75% | |
| Calibration cycle | 6 months | |